Continuous Disinfection, Engineered as a System

AdaptUV™ is the intelligent disinfection platform that powers AeroClenz’s continuous protection promise. Where other solutions rely on scheduled cleaning or isolated UV devices, AdaptUV™ integrates advanced 265 nm UV-C LED technology, dual-presence detection, mmWave radar, radio-frequency tracking, and a mechanical iris into a single automated system one engineered to disinfect air and surfaces throughout the day without disrupting the people, activities, or workflows within your space.

AdaptUV™ doesn’t just clean. It senses, decides, and acts continuously.

AdaptUV™: Engineered to Protect. Automated to Perform.

How AdaptUV™ Works

Aeroclenz AdaptUV Modes

AdaptUV™ operates on a Four-Mode Operating Framework, cycling automatically between modes based on real-time occupancy data:

  • Standby Mode: The system monitors the space continuously, awaiting a change in occupancy status before taking action.

  • Disinfection Mode: When the space is unoccupied, the mechanical iris opens, the blue indicator light activates, and the 265 nm UV-C LEDs engage to disinfect air and exposed surfaces.

  • Clean Air Mode: Once disinfection completes, the iris closes and the green indicator light confirms the cycle is finished.

  • Fault Mode: If a fault is detected, red LEDs flash to alert facility staff no guesswork, no ambiguity.

The system repeats this cycle automatically, all day, every day, without requiring staff to position, operate, or reset the unit. You don’t manage AdaptUV™. It manages your air and surfaces.

AdaptUV™: Engineered to Protect. Automated to Perform.

265 nm UV-C LED Technology

Germicidal effectiveness starts with wavelength precision, and AdaptUV™ is built around it.

  • Peak Germicidal Wavelength: AdaptUV™ operates at 265 nm the wavelength optimized to target disease-causing microorganisms, including viruses, bacteria, fungi, mold, and parasites.

  • Solid-State Reliability: Advanced UV-C LEDs replace the fragile glass, toxic mercury, and high-voltage requirements of legacy UV lamp systems, delivering a more durable and serviceable design.

  • 900 mW Radiometric Power: Each unit delivers 900 mW of radiometric power at 20W of input power, producing 80 µW/cm² of irradiance at 1 meter engineered for high-precision disinfection without excess energy draw.

The right technology, at the right wavelength, attacking pathogens where they form. That’s the AdaptUV™ difference.

AdaptUV™: Engineered to Protect. Automated to Perform.

Air + Surface Disinfection, Proven by the Numbers

Before and After Pathogen Treatment Aeroclenz

AdaptUV™ doesn’t just promise disinfection it quantifies it.

  • Air Disinfection: In a 700 ft³ room, AdaptUV™ achieves 99.9% SARS-CoV-2 air deactivation in approximately 10 minutes.

  • Surface Disinfection: On a 36 ft² counter surface, AdaptUV™ achieves 90% E. coli deactivation in approximately 3.1 minutes.

  • Spore Deactivation: On the same surface area, AdaptUV™ achieves 90% spore deactivation in approximately 64 minutes.

These aren’t projections. They’re measured outcomes, calculated against defined room volumes, surface areas, and dosage levels. Facility-specific results vary, which is why every AdaptUV™ deployment begins with a facility assessment not a guess.

AdaptUV™: Engineered to Protect. Automated to Perform.

Intelligent Presence Detection

Intelligent Presence Detection with Aeroclenz

Safe, automated disinfection depends on knowing with certainty who is in the room. AdaptUV™ uses a Dual-Presence Detection Framework to make that determination continuously:

  • mmWave Radar: Detects both moving and stationary occupants, including subtle movements that passive sensors can miss.

  • PIR + 2.4 GHz Radar Sensors: Working in tandem across a 120° detection field-of-view, these sensors confirm occupancy status before any UV-C operation begins.

  • Radio-Frequency Tracking: Adds a further layer of occupancy confirmation, reducing the risk of false negatives in complex or high-traffic spaces.

Two detection systems. One decision: disinfect only when it’s safe to do so.
AdaptUV™: Engineered to Protect. Automated to Perform.

Mechanical Iris Technology

AdaptUV System Aeroclenz

The mechanical iris is AdaptUV™’s physical safeguard a hardware-level control that works in concert with its sensing systems.

  • Closed by Default: The iris remains closed during Standby and Clean Air modes, physically containing UV-C emission when disinfection isn’t active.

  • Opens Only When Confirmed Unoccupied: The iris opens exclusively during Disinfection Mode, after presence detection confirms the space is clear.

  • Closes Instantly on Re-Entry: If presence is detected mid-cycle, the iris closes and UV-C shuts off immediately, returning the system to a safe state.

It’s not just software telling the system what to do. It’s hardware enforcing it.

AdaptUV™: Engineered to Protect. Automated to Perform.

Safety Engineering

Aeroclenz provides safe disinfection

AdaptUV™’s safety architecture is built on redundancy, not assumption. The system layers multiple independent safeguards so that no single point of failure compromises occupant safety:

  • No Ozone Emissions: AdaptUV™ disinfects without releasing harmful ozone gas into the space.

  • No Mercury: Solid-state LED technology eliminates the toxic mercury found in legacy UV lamp systems.

  • Automatic UV-C Shutoff: Presence detection and the mechanical iris work together to halt UV-C operation the instant occupancy is detected.

  • Visual Status Indicators: Blue, green, and red LED indicators communicate the system’s operating mode at a glance, so facility staff always know the system’s status.

  • Compact, Ceiling-Mountable Design: At 125 x 63 mm and 467 g, AdaptUV™ installs discreetly overhead, out of reach and out of the way.

AeroClenz systems are not medical devices and are intended as an adjunct to existing housekeeping practices not a replacement for them. AdaptUV™ adds a layer of protection. It doesn’t add a task to your team’s workload.

AdaptUV™: Engineered to Protect. Automated to Perform.

Technical Specifications

Parameter Value
Wavelength 265 nm
Radiometric Power 900 mW
Irradiance at 1 m 80 µW/cm²
Input Power 20 W
Input Voltage 12V DC
Unit Dimensions 125 x 63 mm
Weight 467 g
Presence Sensors 2.4 GHz radar + PIR
Sensor Detection
Field-of-View
120°
Mounting Ceiling-mountable

AeroClenz, LLC EPA Company # 105393. AeroClenz systems are not medical devices and are not intended for any level of microbial reduction on medical devices. Independent studies available upon request.

See AdaptUV™ in Your Facility

Every space is different airflow, occupancy patterns, high-traffic zones, and operational requirements all shape how AdaptUV™ should be deployed. A Facility Assessment is how we map that out, before a single unit is installed.

AdaptUV™: Engineered to Protect. Automated to Perform.